Features of photovoltaic DC surge protector:
- Improve system stability: photovoltaic surge protector can quickly consume surge voltage or current to avoid system crash, thereby enhancing system stability.
- Extend system life: By reducing the impact of environmental factors on the system, photovoltaic surge protector helps to improve system durability and extend service life.
- Improve system safety: Protect the system from damage by surge voltage and current, reduce maintenance costs and risks, and improve overall safety.
- Self-protection and fault indication function: When the protection device is aged or damaged, it can disconnect from the circuit in time, and notify the user to replace it through visual or remote signals, improving the reliability and safety of the system.
Model | KNSP-40R 2P |
Poles | 3 |
Brand Name | Korlen |
Type | T2 |
Rated Voltage | 1000V |
Max Discharge Current | 40A |
TA | 25ns |
Place of Origin | Zhejiang China |
Test Standard | IEC 61643-11 |
Certificate | CE Certification |
Warranty | 3 Years |
Function | Lighting Protection |
Color | Orange |
Material | Thermoplastic UL94-V0 |
Technical Data
SPD Type | Type 1+2/Class l+ll | |||
Technology | Mov(Metal oxide varistors) | |||
Protection mode(s) | DC+PE.DC~/PE | |||
Nominal voltage (D.c.) [Ucpv] | 600V | 800V | 1000V | 1200V |
Nominal discharge current(8/20μs) [ln] | 20kA | |||
Max.discharge current (8/20μs) [lmax] | 50kA | |||
Lightning impulse current (10/350μs) [limp] | 6.25kA | |||
Total discharge current for multi-pole SPD [ltotal] | 12.5KA | |||
Protection level [Up] | ≤3.2kV | ≤3.6kV | ≤4.0kV | ≤4.5kV |
Response time [tA] | ≤25ns | |||
Admissible short-circuit current [lsccr] | 25kA | |||
Max,backup fuse | 125A gL/Gg |
Mechanical Data
Technology | MOV(Metal Oxide Varistors)+GDT |
SPD configuration | DC system |
Plug-able | Available |
Mounting | 35mm DIN rail |
Housing material | Thermoplastic,UL 94 V-O |
Operating temperature | -40℃~+80℃ |
Protection rating | IP20 |
Operating state /fault indication | Green/Red |
Remote Signaling | Optional |
Wiring for remote signaling | Max 1.5mm solid/flexible |
Max. Voltage/Current for remote signaling | 250V/0.1A:125V/0.2A:75V/0.5A |
Test Standards | IEC 61643-31/EN61643-31 |
Certificate | CE, TUV, ROHS, CB |
IEC,GB/T Standard | DC500V | DC600V | DC800V | DC1000V | DC1200V | DC1500V |
Maximum continuous working DC voltage (DC+)-PE,(DC-)-PE,UCPV (DC+)-(DC) | 500V | 600V | 800V | 1000V | 1200V | 1500V |
Nominal discharge current In | 20kA | |||||
Lightning discharge current limp | 6.25kA | |||||
Total discharge current ITotal | 12.5KA | |||||
Total discharge current ITotal | 40KA | |||||
Maximum discharge current lmax | 40KA | |||||
Voltage protection level (DC+)-PE,(DC-)-PE, UP (DC+)-(DC) | ≤1800V | ≤2200V | ≤2500V | ≤3500V | ≤4000V | ≤4500V |
Response time Ta | 25ns | |||||
Short-circuit current rating ISCPV | 2000A | |||||
Mechanical and environmental characteristics | / | |||||
Operating temperature range | -40°F~+158°F(-40℃ ~+70℃) | |||||
Allowable operating humidity | 5%~95% | |||||
Atmospheric pressure and altitude | 80k Pa~106kPa/-500m~2000m | |||||
Terminal screw torque | 39.9 lbf.in [ 4.5Nm ] | |||||
Maximum wire cross-sectional area | 2AWG (stranded wire)/4AWG [flexible wire) 35mm’ (stranded wire)/25mm’ (flexible wire) | |||||
Installation | 35mm DIN rail, according to EN60715 | |||||
Protection level | IP20 | |||||
Casing material | Thermoplastic material: Fire extinguishing grade UL94V-0 | |||||
Thermal protection | Yes | |||||
Working status/fault indication | Green/Red | |||||
Remote signal contact | Optional | |||||
AC/DC switching capability | AC:250V/0.5A:DC:250V10.1A:125V/0.2A:75V/0.5A | |||||
Appearance color | White/Grey/Red |